ul 1 hour shaft wall assembly

Shaft Wall Solutions for Wood-Frame Buildings: Codes & Detailing - Civil

Several options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC Table 721.1 (2), Item 14-1.3 UL U332 1-Hour Double Wall UL U341 2-Hour Single wall UL U301 UL U334 IBC Table 721.1 (2) Item Number 14-1.5

Exterior Wall System Testing and Certification | UL Solutions

Meet exterior wall system requirements Exterior wall assemblies are designed to resist the impacts of fire, wind, rain, hail, extreme temperatures and sound, and be energy efficient, attractive and much more. We understand these challenges. We provide testing, inspection, and certification solutions for exterior wall assemblies.

Looking For Better Rated Horizontal Membrane Assemblies? - National Gypsum

6/23 · UL design G586 can span 8’-0” from wall to wall or indefinitely when used in conjunction with the hanger assembly. For 1-hour assemblies, National Gypsum developed UL design I504, which is a 1-hour horizontal assembly that consists of 3-5/8” steel studs 16” o.c. with three layers of 5/8” Type X gypsum board applied to the underside of the framing.

UL U415 System B - Wall Assembly - Knauf Insulation North America

UL U415 System B Shaft Wall, Steel Stud (Non-Load-Bearing) Stc 37 Fire Rating 2 Hour System Thickness 3-3/4" PDF (276.2 KB PDF) REVIT (1.99 MB RVT) CAD (66.60 KB DWG) Assembly Details Gypsum Board 1" thick Thick Gypsum Liner Panel (UL Type SLX) Steel Studs 2-1/2" thick CH Studs, 20ga. MSG., Spaced 24" O.C. Gypsum Board

ANSI/UL 263 BXUV.U499 Fire Resistance Ratings

Design/System/Construction/Assembly Usage Disclaimer U499. April 26, 2010. Nonbearing Wall Rating — 1 Hr. 1. Channel Track — "J" -shaped 

BXUV.U415 - Fire-resistance Ratings - ANSI/UL 263 - BuildSite

Fire resistance assemblies and products are developed by the design submitter and have been Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr.

What You Should Know About Cavity Shaftwalls

Can horizontal shaftwall assemblies be used for a rated corridor ceiling? National Gypsum's UL Cavity Shaftwall Systems (1-4 hour) 

Shaft Wall - Construction

Fire-Rated Assemblies 3 USG Shaft Wall Systems 09 20 00/USG BuyLine 2425 1 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Construction Detail Description Test Number STC Test Number wt. 8 † 5/8 SHEETROCK® brand FIRECODE® Core gypsum UL

One Hour Fire Rated Assemblies - Structural building components

Answer: Generally, there are two types of 1-hour wood truss assemblies: the first is one layer GWB with metal furring strips or resilient channel, and the second is two layers GWB board. An

ClarkDietrich Shaftwall Systems | ClarkDietrich Building Systems

Shaftwall systems are interior nonload-bearing fire rated wall assemblies that provide critical, life safety, fire-resistant protection for elevator shafts, stairwells, vertical chases and mechanical enclosures. Shaftwalls in elevators and stairwells are one of the most important wall assemblies in a building.

AER-09038 - CEMCO

One-Hour Cavity Shaft Wall (Non-Load Bearing), See Figure 1 1. A minimum 2-1/2" wide 24 gauge floor and ceiling J-runners, attached to structure as described above. 4. 1" thick Sheetrock®Brand Gypsum Liner Panel- UL Type SLX, Friction