Characteristics Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, Product

GV2ME08 Thermal-Magnetic Tripping Curves for GV2ME and GV2P Average Operating Times at 20 °C Related to Multiples of the Setting Current 1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V)) Dynamic Stress I peak = f (prospective Isc) at 1.05 Ue

Motor guard circuit GV2ME08 TeSys Schneider - Adajusa

Overload (Thermal). Phase failure. Features: Manufacturer: Schneider Electric. Range: Tesys. Reference: GV2ME08; Maximum operating voltage (Ue): 690 V 50 

Motor circuit breaker GV2ME08 / # Z c2m 2766

Motor circuit breaker GV2ME08 / # Z c2m 2766. Motor circuit breaker GV2ME08 / # Z c2m 2766. Item Information. Condition: Used Used. Price: US $40.01. Motor circuit breaker GV2ME08 / # Z c2m 2766. Sign in to check out Check out as guest. Adding to your cart. The item you've selected was not added to your cart.

GV2ME08 - Schneider Electric - Circuit Breaker, Motor Protection

The GV2ME08 is an enclosed Motor Circuit Breaker with thermal-magnetic trip unit technology. It is DIN rail mountable with vertical and horizontal mounting positions. The addition of an under-voltage trip enables the motor circuit-breaker to be tripped if voltage is lost. The addition of a shunt trip enables remote control of tripping.

Schneider Electric GV2ME08 Schneider Electric 4 AMP Circuit

The GV2ME08 manual starter and protector provides manual isolation, manual motor control, and overcurrent protection in one compact unit. The GV2 series has a standard set of accessories, including front mounted GVAE11 auxiliary contacts, side mounted GVAN11 auxiliary contacts as well as undervoltage trips to complete the unit.

Product data sheet GV2ME08

GV2ME08 Thermal-Magnetic Tripping Curves for GV2ME and GV2P Average Operating Times at 20 °C Related to Multiples of the Setting Current 1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V)) Dynamic Stress I peak = f (prospective Isc) at 1.05 Ue

Schneider Electric GV2ME08 Manual Protector | 2.5 to 4 AMPS

Product Description Schneider Electric / Telemecanique GV2ME08 manual starter and protector with ON/OFF push button design and an adjustable thermal trip setting from 2.5A-4A. The GV2 motor protectors are a manual disconnect with Class 10 (trips in 10 seconds or less) ambient compensated overload relay and an magnetic instantaneous trip mechanism.

Schneider Electric GV2ME08 Non-Reversing Manual

Schneider Electric GV2ME08 MANUAL STARTER 600VAC 4AMP IEC,-2060 deg.C,0.125HP115VAC - 0.334HP230VAC 0.75HP200VAC - 1HP230VAC - 2HP460VAC - 3HP575VAC 

GV2ME08 Telemecanique In stock and ready to ship

Buy GV2ME08 / GV2 ME08 Telemecanique Tesys Gv2-Circuit Breaker-Thermal-Magnetic - 2.54 A - Screw Clamp Terminals from Distributor Santa Clara Systems.

GV2ME08 Schneider Electric - Mouser Electronics

GV2ME08 Schneider Electric Motor Drives MAN-START 600VAC 4AMP IEC datasheet, inventory, & pricing.

GV2ME08 Schneider Electric | Mouser Canada

Isolated DC/DC Converters 18-75Vin 12V 1250mA 15W DIP 1x1 Iso Reg. QuickView. Stock: 119. 119. No Image. PIC32MK0256MCJ064-E/R4X. PIC32MK0256MCJ064-E/R4X. 32-bit Microcontrollers - MCU PIC32MK, 256K Flash, Motor Control Features, CAN-FD, 64 Pin QFN. QuickView.